TM 10-3930-660-10
0005 00-2
OPERATION UNDER USUAL CONDITIONS - CONTINUED 0005 00
OPERATE ENGINE - CONTINUED
3. If the travel select lever is not in the neutral position, move the lever to Neutral “N”.
4. On the first start of the day, check the neutral switch for proper operation.
a. Place the travel select lever in the Forward, “F” position.
b. Ensure that the auxiliary fuel shut-off switch is in OFF position.
CAUTION
If the engine turns over, do not continue. This indicates that the neutral safety switch is defective.
c. Turn the starter-run control switch to the START position. The engine should not turn over.
d. Return the starter-run control switch to the OFF position.
e. Return the travel select lever to the Neutral, “N” position.
f. Place the auxiliary fuel shut-off switch to the ON position.
5. Press the accelerator pedal to approximately half speed.
CAUTION
Do not crank the staring motor for more than 30 seconds at a time. Continuous cranking can overheat and
damage the starting motor.
6. Turn the starter-run control switch clockwise to the START position. Release the switch as soon as the engine starts. If the
engine fails to start on the first try, wait until the engine and starter have come to a complete stop. Then, return the switch
to the OFF position before attempting to start again.
CAUTION
If the coolant temperature exceeds 220°F (104°C) or the warning light is illuminated, shut the engine down
immediately. Do not operate the vehicle continuously at a water temperature above 210°F (99°C) or
below 140°F (60°C).
409-023
AUXILIARY FUEL
SHUT-OFF SWITCH
Komentáře k této Příručce