TM 10-3930-660-10
0012 00-14
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED 0012 00
Table 1. Preventive Maintenance Checks and Services (PMCS) for 6K Forklift - Continued.
Item
No. Interval
Man-
Hours
Location
Procedure
NOT FULLY MISSION
CAPABLE IF:
Item To
Check/
Service
WARNING
• DO NOT smoke or permit any open flame in area of vehi-
cle while you are service diesel fuel systems. Be sure hose
nozzle is grounded against filler tube during refueling to
prevent static electricity. Failure to follow this warning
may result in injury to personnel or equipment damage.
• Operating personnel must wear fuel-resistant gloves when
handling fuels. If exposed to fuel, promptly wash exposed
skin and change fuel-soaked clothing.
NOTE
• Place portable fire extinguisher within reach prior to refu-
eling.
• DO NOT overfill fuel tank. If fuel starts foaming from fuel
tank, stop IMMEDIATELY to avoid fuel spillage.
43 After Fuel
Tank
a. Check fuel tank filler tube and
cap for damage or leaks.
a. Any fuel leaks or damage are
noted.
b. Remove fuel tank filler cap.
Inspect cap gasket for damage.
b. Fuel cap gasket is missing or
damaged.
c. Check strainer to ensure it is
clean. Remove strainer and
clean as required.
d. Add fuel (Item 6, WP 0025 00)
to tank. Do NOT overfill.
Reinstall fuel cap and secure.
Komentáře k této Příručce