TM 10-3930-660-10
0012 00-6
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED 0012 00
Table 1. Preventive Maintenance Checks and Services (PMCS) for 6K Forklift - Continued.
Item
No. Interval
Man-
Hours
Location
Procedure
NOT FULLY MISSION
CAPABLE IF:
Item To
Check/
Service
14 Before Center of
Boom
Check that boom hoses and elec-
trical cable are snug against ten-
sioner and not crossed or worn.
Hoses or cable are crossed, worn
or obviously loose.
CAB
INTE-
RIOR
15 Before Fire
Extin-
guisher
a. Visually check for missing or
damaged fire extinguisher.
Ensure it is securely mounted
behind seat.
Fire extinguisher is missing or
damaged.
b. Check gage for reading in
green area of gage.
Pressure gage needle is in
recharge (red) area.
c. Check for broken or missing
seal.
Seal is broken or missing.
409-3000
ELECTRICAL
CABLE
HYDRAULIC
HOSES
409-3005